• UOP 755-13
Provide PDF Format

Learn More

UOP 755-13

  • Trace Impurities in High Purity Ethyl Benzene by GC
  • standard by UOP LLC, A Honeywell Company, 03/01/2013
  • Publisher: UOP

$110.00$220.00


This method is for determining trace impurities in high purity ethyl benzene by gas chromatography (GC). Specific impurities identified include benzene, toluene, p-xylene, m-xylene, o-xylene, cumene, n-propylbenzene, 1,2-diethylbenzene, 1,3-diethylbenzene, and 1,4-diethylbenzene. Non-aromatics and unidentified C9+ aromatics are determined as composites. Benzene and toluene may not be separated from the non-aromatic impurities by this method but, if required, may be determined individually by UOP Method 543, “Trace Non-Aromatic Hydrocarbons in High-Purity Aromatics by Gas Chromatography.” The lower limit of detection for any single component is 2 mg/kg (massppm) except for p-xylene, which has a lower detection limit of 10 mg/kg.

Related Products

UOP 551-86

UOP 551-86

Hexanes and Lower Boiling Hydrocarbons in Olefin Free Gasolines by GC..

$132.00 $263.00

UOP 883-95

UOP 883-95

Purity of UOP No. 5 Inhibitor by Capillary Column GC..

$128.00 $256.00

UOP 833-82

UOP 833-82

Molybdenum in Platforming Catalysts and Fines by Atomic Absorption Spectrophotometry..

$128.00 $256.00

UOP 405-67T

UOP 405-67T

Hydrogen Chloride in Gas Streams by Potentiometric Titration..

$128.00 $256.00