Need: The integrity of the liquid pipeline network in the United States is of concern to the pipeline operators, the surrounding communities, and the government. During a recent Office of Pipeline Safety industry forum, concerns regarding the detection of small liquid leaks were discussed. The important topic areas related to small leak detection included identifying the available real-time monitoring and detection systems, assessing the need for new detection technologies, and understanding the performance of currently available systems.

Result: The member companies of the Pipeline Research Council International, Inc. (PRCI) sponsored a gap analysis study of detection of small leaks in liquid pipelines. The objective of the gap analysis project was to assess the gap between what liquid pipeline operators need in terms of leak detection and what various leak detection technologies can provide, specifically related to small leaks. For this gap analysis study, small leaks were considered to be pipeline releases that were less than 5% of nominal pipeline flow rate.

Benefit: Many of the gaps identified during the study focused on improving Computational Pipeline Monitoring (CPM) systems, since all of the operator respondents used these systems in some manner. Potential advancements for these systems hinged upon improving instrumentation and the modeling of complex conditions, such as slack line flow. Another key gap was the desire to lower the frequency of non-leak alarms without compromising leak detection sensitivity. Additional gaps were related to further investigation into external leak detection systems, since they might offer improved performance. The main identified gap regarding external systems was the lack of documented operational information.

Related Products

PRCI PR-238-9502

PRCI PR-238-9502

Non-Destructive Assurance of Quality of Heat Treated Fittings..

$98.00 $195.00

PRCI PR-185-9332

PRCI PR-185-9332

Development of Fitness-for-Purpose Assessment Procedures for Branch Welds..

$25.00 $49.00

PRCI PR-185-9430

PRCI PR-185-9430

Development of Modeling Procedures for Branch Welds..

$75.00 $149.00

PRCI PR-244-04404

PRCI PR-244-04404

Limit State Function Development for the Application of Reliability Based Design and Assessment to ..

$98.00 $195.00